Quarto Lav Low Flow

The water flow on the quarto bathroom faucet is slow

The quarto lav faucet has a standard 1.2 GPM restrictor. If for some reason this restrictor needs to be removed, please follow the steps below:

1. Turn the water off to the faucet
2. Remove handle and cartridge
3. On the bottom of the cartridge, there should be a pink restrictor pushed in.
4. Pry it out with a pick tool.
5. Re-install cartridge.

Please use the video link below to assist in removing the restrictor.

Quarto Lav Flow Restrictors